产品展示

煤矿用阻燃同轴射频电缆

煤矿用阻燃同轴射频电缆

详细说明:

     产品用途:产品适用于煤矿井下无线电通讯设备和采用类似技术的电子装置的有关无线电子设备中传输射频信号。 
      Scope of application:The product is fit for the transmission of radio frequency signals in radio equipment or in electronic equipment adopting similar technologies.
      执行标准 Standards implemented: Q/3210HL32-2005

    型号规格及尺寸范围 Model specifications and sizes application


    型 号
    Model

    内导体(根数/直径mm)
    Inner conductor
    (core No./dia)

    标称绝缘外径mm
    Nominal insulation outerdiameter

    标称电缆外径mm
    Nominal cable outer diameter

    MSYV-50-2-1

    7/0.16

    1.5

    2.8

    MSYV-50-2-41

    1/0.68

    2.2

    4.0

    MSYV-50-3-1

    7/0.32

    2.95

    5.0

    MSYV-50-3-41

    1/0.9

    2.95

    5.8

    MSYV-50-5-1

    1/1.4

    4.8

    7.2

    MSYV-50-5-3

    1/1.4

    4.8

    7.2

    MSYV-50-7-1

    7/0.76

    7.3

    10.3

    MSYV-50-7-2

    7/0.76

    7.3

    10.5

    MSYV-50-9-41

    7/0.95

    9.0

    12.2

    MSYV-50-12-1

    7/1.15

    11.5

    15.0

    MSYV-75-2

    7/0.08

    1.5

    2.9

    MSYV-75-3-41

    7/0.17

    3.0

    5.0

    MSYV-75-5-41

    1/0.75

    4.8

    7.2

    MSYV-75-5-42

    1/0.75

    4.8

    7.9

    MSYV-75-7-1

    7/0.40

    7.3

    10.3

    MSYV-75-7-41

    7/0.40

    7.3

    11.0

    MSYV-75-9-41

    1/1.37

    9.0

    12.2

    MSYV-75-12-2

    7/0.64

    11.5

    15.0

    MSYV-75-15-41

    7/0.82

    15.0

    19.0

    MSYV-100-7

    1/0.6

    7.3

    10.2

      电缆结构示意图 IIIustration of cable structure
     
      使用特性 Service characteristics

    电缆导体最高工作温度
    Electric cable conductor Max. temperature

    70℃

    最低环境温度
    Lowest ambient temperature

    固定敷设为-40℃,非固定敷设为-15℃
    Fixed placing-40℃,Non-fixed placing -15℃

    +40℃环境相对湿度
    Environment relative humidity at 40℃

    ≤98%

    电缆的最小弯曲半径
    Minimun bending radius

    电缆外径的5倍(在室内);电缆外径的10倍(在室外)
    Cable outer diam 5 times(In room);cable outer diam 10times(In outside)

      电缆主要技术性能 Major technical performances


    型 号
    Model

    标称特性阻抗(Ω)
    characteristic
    impedance

    衰减常数
    attenuation constant

    额定电容(PF/m)
    Rated capacitance

    试验电压(KV)
    Test voltage

    绝缘电阻
    (≥MΩ·Km)
    Insulation
    resistance

    频率(MHz)
    frequency

    衰减(≤db/m)
    attenuation




    MSYV-50-2-1

    50

    200

    0.45

    100

    2.0

    5000

    MSYV-50-2-41

    0.31

    3.0

    MSYV-50-3-1

    0.24

    4.0

    MSYV-50-3-41

    0.22

    4.2

    MSYV-50-5-1

    0.15

    6.5

    MSYV-50-5-3

    0.15

    6.5

    MSYV-50-7-1

    0.11

    10.0

    MSYV-50-7-2

    0.11

    10.0

    MSYV-50-9-41

    0.095

    12.0

    MSYV-50-12-1

    0.080

    15.0

    MSYV-75-2

    75

    0.579

    67

    1.5

    MSYV-75-3-41

    0.28

    2.0

    MSYV-75-5-41

    0.15

    5.5

    MSYV-75-5-42

    0.15

    5.5

    MSYV-75-7-1

    0.12

    8.0

    MSYV-75-7-41

    0.12

    8.0

    MSYV-75-9-41

    0.088

    10.0

    MSYV-75-12-2

    0.088

    12.5

    MSYV-75-15-41

    0.066

    16.0

    MSYV-100-7

    100

    0.147

    57

    5.0

      电缆其它主要技术性能 Other major technical performances

    单根垂直燃烧试验
    Single wire burning test

    MT386

    成束燃烧试验
    Group burning test

    符合GB/T 18380.3标准中B类中成束试验要求
    Conforms to GB/T18380.3 standard B kind group burning test


下一篇:没有了;  上一篇:煤矿用控制电缆